60W LED Wall Pack - Bypassable Photocell - 9,000 Lumens - 175W Metal Halide Equivalent - 4000K / 5000K
Features
- Reduces maintenance and energy costs
- Integrated bypassable photocell for dusk-to-dawn operation
- 175W metal halide equivalency
- DLC 5.1 Premium
Loading recommendations...
Overview
- Bronze die-cast aluminum housing and polycarbonate lens
- IP65 weatherproof rating
- Easily bypass the integrated photocell by unplugging the sensor
- Photocell operation: on < 30 lx, off > 60 lx
- 120-277 VAC
- Certified by UL
- DLC 5.1 Premium
- 5-year warranty
Need help?
Use our Lighting Layout Tool to see how this product illuminates your space.
Specifications
Ambient Operating Temperature | -40~+50 °C (-40~+122 °F) |
---|---|
Beam Angle | 105° |
Brand | Super Bright LEDs |
Certifications/Compliance
Certifications/Compliance
Standards and certifications comprise a vast number of companies and compliances that serve specific purposes—primarily addressing safety, environmental impact and energy efficiency, and sanitation. They are divided into categories for each product type and certification type to allow for very specific qualifications related to each product. When this system is being used as intended, it gives consumers, installers, suppliers, and anyone else that may be involved confidence that the product is safe and will work well in their application. The most common UL and ETL certifications relate to safety and installation, although they do also provide some sanitation-related certifications (using NSF standards). Another common certification body is the DLC, which specializes in certifying the performance of a light—mainly related to environmental impact and electrical efficiency. Learn more about different certification types here . |
Certified by UL, DLC Premium |
CRI
CRI
|
80+ |
Current Draw
Current Draw
Current draw is calculated using the following formula: W/V = A, where W = the amount of power your light needs (wattage), V is the electrical system voltage (e.g., 120V AC), and A = amps. An ampere or amp (A) is the standard unit for electrical current. A milliamp (mA) equals one-thousandth of an amp, or 1000 mA is equivalent to 1 A.
Choosing LED fixtures with the correct amperage ensures safe and proper operation, preventing damage or injury. We recommend having all electrical components and fixtures installed by a certified professional electrician or lighting technician in compliance with all relevant standards and regulations. |
220 mA @ 277 VAC, 500 mA @ 120 VAC |
Dimmable | Yes |
Dimmer Type
Dimmer Type
|
0-10V |
Distribution Type
Distribution Type
|
Type IV-VS |
Efficacy | 150 lm/W |
Environmental Rating
Environmental Rating
|
Suitable for Wet Locations, Waterproof |
Equivalency | 175 Watt Metal Halide |
Finish | Bronze |
Input Connection Type | Pigtail |
Integrated Surge Protection | 4 kV (L-N), 6 kV (L/N-G) |
IP Rating
IP Rating
|
IP65 |
Rated Life (L70) | 50000 Hours |
Lens Type | Polycarbonate |
Lumens | 9000 Lumens |
Operating Voltage | 120-277 VAC |
Photocell
Photocell
What is a Photocell and How Does It Work?When an LED light is equipped with a photocell, the light will turn on and off automatically based on the available ambient light. Their unique functionality makes them ideal for outdoor area lighting specifically.Photocells are variable resistors that change the resistance in an electrical circuit depending on the amount of light present where they are mounted. Because of this, they must be mounted in exposed areas where they receive adequate light to function. Photocells, or photocontrols, come in a variety of shapes and sizes and can be integrated into a luminaire or be an added accessory depending on the light. Can a Photocell Be Bypassed?Some lights allow for a photocell to be bypassed as needed. When the photocell is bypassed, it allows for the luminaire to remain on constantly or be controlled by an existing switch or timer. Depending on the type of photocell and how it is installed in the fixture, it may be bypassable using a shorting cap, a slide or DIP switch, or by unplugging the photocell. Consult the user’s manual of the light to confirm which option(s) may be applicable and how to implement them safely. Always use caution and turn off supply power before working on wiring of any type.Shorting CapPhotocells on many commercial applications like parking lot and area lighting applications are mounted externally with a twist-lock socket or adapter. Swapping this for a shorting cap simply closes the circuit on your LED light fixture, which keeps your light in an always-on state. This allows it to be controlled externally as well if a central photocell or switch system is being utilized.DIP Switch or Slide SwitchWhile DIP switches and standard slide switches function differently in most cases, when integrated into the photocontrol system of a light they perform the same function. Switches like these are common on canopy and dusk-to-dawn barn lights. These types of switches allow you to toggle the photocell sensor on or off to fit your needs without any rewiring or replacing parts.Disconnect the WiringSome photocell designs, such as those commonly found in wall packs, allow the operator to simply unplug the photocell to allow the light to work in an always-on state or be controlled by an external switch. |
Integrated Photocell (Bypassable) |
Power Factor | ≥0.9 |
Product Materials | Aluminum Housing, Polycarbonate Lens |
Product Weight | 5.3 lb (2.4 kg) |
UL File Number | E366643 |
Warranty | 5 Year |
Wattage | 60 Watts |
Wire Gauge | 18 AWG |
Part NO |
CCT
CCT
|
LED Color |
---|---|---|
WP3-40K60P-BABRSP | 4000K | Natural White |
WP3-50K60P-BABRSP | 5000K | Cool White |
Accessories & Power Supplies
Reviews
Review Guidelines
Super Bright LEDs reads and approves all reviews before listing them on the website. Below you will find a list of reasons that can result in your review being rejected.
- Review text does not pertain to the product
- Photos are not related to the reviewed product
- Any violation of laws and/or copyrighted material
- Unrelated hyperlinks/URLs