12 VDC ENCLOSED SWITCHING POWER SUPPLY
• INTERNATIONAL AC INPUT RANGE
• HIGH EFFICIENCY, LOW WORKING TEMPERATURE

• SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT

• SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED

• COMPACT SIZE, LIGHT WEIGHT
• 100% FULL LOAD BURN-IN TEST
• BUILT IN EMI FILTER, LOW RIPPLE NOISE
• LOW COST, HIGH RELIABILITY
 

SPECIFICATION
DC OUTPUT VOLTAGE
12V
12V
12V
12V
OUTPUT V. TOLERANCE
±1%
±1%
±1%
±1%
OUTPUT RATED CURRENT
2.1A (2100ma)
3.5A (3500ma)
5A (5000ma)
8.3A (8300ma)
To determine how many LED bulbs can be connected to a power supply: divide the total current capacity of the power supply by the current draw of one bulb
OUTPUT CURRENT RANGE
0-2.1A
0-3.5A
0-5A
0-5A
RIPPLE & NOISE
100mVp-p
100mVp-p
120mVp-p
120mVp-p
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
DC OUTPUT POWER
25.2W
42W
60W
100W
EFFICIENCY
76% / 115VAC
76% / 115VAC
76% / 115VAC
76% / 115VAC
DC VOLTAGE ADJ.
±10%
±10%
±10%
±10%
INPUT VOLTAGE RANGE 85~264VAC 47~63 Hz; 120~370VDC
AC CURRENT  0.6A/115VAC 0.3/230V
INRUSH CURRENT  COLD START 15A/115V  30A/230V
LEAKAGE CURRENT 0.75mA/240VAC
OVERLOAD PROTECTION  105%~150% TYPE: PULSING HICCUP SHUTDOWN RESET:AUTO RECOVERY
OVER VOLTAGE PROTECTION  115%~135%
TEMP. COEFFICIENT  ±0.03% / °c (0~50°C)
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 10ms / 115VAC   300ms, 50ms, 80ms / 230VAC
VIBRATION 10-500Hz, 2g 10min./1 cycle, PERIOD FOR 60 min. EACH AXIS
WITHSTAND VOLTAGE  I/P-O/P, I/P-FG:1.5KVAC   O/P-FG:0.5KVAC
ISOLATION RESISTANCE  I/P-O/P, I/P-FG:500VDC / 100M Ohms
WORKING TEMP., HUMIDITY -10°C~+60°C, 20%~90% RH
STORAGE TEMP., HUMIDITY -20°C~+85°C, 10%~95% RH
SAFETY STANDARDS UL1012, TUV EN60950, IEC950, UL1950 APPROVED
EMC STANDARDS CISPR22 (EN55022), IEC801-12,3,4, IEC555-2 VERIFICATION
NOTES:
1. ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25°C 70% RH AMBIENT
2. TOLERANCE: INCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION
3. RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR
4. LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD
5. LOAD REGULATION IS MEASURED FROM 0% TO 100% RATED LOAD
CLICK LINKS BELOW TO SEE COMPLETE SPECIFICATION AND DIMENSIONAL DRAWINGS
12 VDC COMPACT POWER SUPPLY
 
SPECIFICATION
PS-15
DC OUTPUT VOLTAGE
12V
12V
12V
OUTPUT RATED CURRENT
1.25A (1250ma)
2.0A (2000ma)
4.1A (4170ma)
To determine how many LED bulbs can be connected to a power supply: divide the total current capacity of the power supply by the current draw of one bulb
OUTPUT CURRENT RANGE
0-1.25A
0-2.0A
0-4.1A
DC OUTPUT POWER
15W
24W
50W
INPUT VOLTAGE RANGE
 100~240VAC; 50~60 Hz
 100~240VAC; 50~60 Hz
100~240VAC; 50~60 Hz

 previous page